From 6bb27d7349db51b50c40534710fe164ca0d58902 Mon Sep 17 00:00:00 2001 From: Stephen Warren Date: Thu, 8 Nov 2012 12:40:59 -0700 Subject: ARM: delete struct sys_timer Now that the only field in struct sys_timer is .init, delete the struct, and replace the machine descriptor .timer field with the initialization function itself. This will enable moving timer drivers into drivers/clocksource without having to place a public prototype of each struct sys_timer object into include/linux; the intent is to create a single of_clocksource_init() function that determines which timer driver to initialize by scanning the device dtree, much like the proposed irqchip_init() at: http://www.spinics.net/lists/arm-kernel/msg203686.html Includes mach-omap2 fixes from Igor Grinberg. Tested-by: Robert Jarzmik Signed-off-by: Stephen Warren --- arch/arm/mach-iop32x/em7210.c | 6 +----- 1 file changed, 1 insertion(+), 5 deletions(-) (limited to 'arch/arm/mach-iop32x/em7210.c') diff --git a/arch/arm/mach-iop32x/em7210.c b/arch/arm/mach-iop32x/em7210.c index 9f369f09c29d..31fbb6c61b25 100644 --- a/arch/arm/mach-iop32x/em7210.c +++ b/arch/arm/mach-iop32x/em7210.c @@ -40,10 +40,6 @@ static void __init em7210_timer_init(void) iop_init_time(200000000); } -static struct sys_timer em7210_timer = { - .init = em7210_timer_init, -}; - /* * EM7210 RTC */ @@ -205,7 +201,7 @@ MACHINE_START(EM7210, "Lanner EM7210") .atag_offset = 0x100, .map_io = em7210_map_io, .init_irq = iop32x_init_irq, - .timer = &em7210_timer, + .init_time = em7210_timer_init, .init_machine = em7210_init_machine, .restart = iop3xx_restart, MACHINE_END -- cgit v1.2.3