From 46bed4dfe5f95f1fc8f68ead592a7e295bbbe01e Mon Sep 17 00:00:00 2001 From: Gong Jun Date: Thu, 18 Jan 2007 22:14:24 +0100 Subject: hwmon/w83793: Ignore disabled temperature channels Ignore the temperature readings when its channel is disabled, ignore AMDSI readings. Signed-off-by: Gong Jun Signed-off-by: Rudolf Marek Signed-off-by: Jean Delvare --- Documentation/hwmon/w83793 | 8 ++------ 1 file changed, 2 insertions(+), 6 deletions(-) (limited to 'Documentation/hwmon') diff --git a/Documentation/hwmon/w83793 b/Documentation/hwmon/w83793 index 45e5408340e0..51171a83165b 100644 --- a/Documentation/hwmon/w83793 +++ b/Documentation/hwmon/w83793 @@ -45,18 +45,14 @@ This driver implements support for Winbond W83793G/W83793R chips. temp5-6 have a 1 degree Celsiis resolution. * Temperature sensor types - Temp1-4 have 3 possible types. It can be read from (and written to) + Temp1-4 have 2 possible types. It can be read from (and written to) temp[1-4]_type. - - If the value of 0, the related temperature channel stops - monitoring. - If the value is 3, it starts monitoring using a remote termal diode (default). - - If the value is 5, it starts monitoring using the temperature sensor - in AMD CPU and get result by AMDSI. - If the value is 6, it starts monitoring using the temperature sensor in Intel CPU and get result by PECI. Temp5-6 can be connected to external thermistors (value of - temp[5-6]_type is 4). They can also be disabled (value is 0). + temp[5-6]_type is 4). * Alarm mechanism For voltage sensors, an alarm triggers if the measured value is below -- cgit v1.2.3