diff options
author | Gao Xiang <gaoxiang25@huawei.com> | 2019-09-04 10:09:00 +0800 |
---|---|---|
committer | Greg Kroah-Hartman <gregkh@linuxfoundation.org> | 2019-09-05 20:10:08 +0200 |
commit | 0259f209487c839e0d5fa0bb82a6e591dd57357a (patch) | |
tree | c586547841258fbec6a712894a24321871874314 /fs/erofs | |
parent | a2c75c8143eaa8f7404dae3df98fe43ebaafce16 (diff) | |
download | linux-0259f209487c839e0d5fa0bb82a6e591dd57357a.tar.bz2 |
erofs: use dsb instead of layout for ondisk super_block
As Christoph pointed out [1], "Why is the variable name
for the on-disk subperblock layout? We usually still
calls this something with sb in the name, e.g. dsb.
for disksuper block. " Let's fix it.
[1] https://lore.kernel.org/r/20190829101545.GC20598@infradead.org/
Signed-off-by: Gao Xiang <gaoxiang25@huawei.com>
Link: https://lore.kernel.org/r/20190904020912.63925-14-gaoxiang25@huawei.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'fs/erofs')
-rw-r--r-- | fs/erofs/super.c | 35 |
1 files changed, 17 insertions, 18 deletions
diff --git a/fs/erofs/super.c b/fs/erofs/super.c index b8b0e35f6621..63cb17a4073b 100644 --- a/fs/erofs/super.c +++ b/fs/erofs/super.c @@ -49,9 +49,9 @@ static void free_inode(struct inode *inode) } static bool check_layout_compatibility(struct super_block *sb, - struct erofs_super_block *layout) + struct erofs_super_block *dsb) { - const unsigned int feature = le32_to_cpu(layout->feature_incompat); + const unsigned int feature = le32_to_cpu(dsb->feature_incompat); EROFS_SB(sb)->feature_incompat = feature; @@ -68,7 +68,7 @@ static int superblock_read(struct super_block *sb) { struct erofs_sb_info *sbi; struct buffer_head *bh; - struct erofs_super_block *layout; + struct erofs_super_block *dsb; unsigned int blkszbits; int ret; @@ -80,16 +80,15 @@ static int superblock_read(struct super_block *sb) } sbi = EROFS_SB(sb); - layout = (struct erofs_super_block *)((u8 *)bh->b_data - + EROFS_SUPER_OFFSET); + dsb = (struct erofs_super_block *)(bh->b_data + EROFS_SUPER_OFFSET); ret = -EINVAL; - if (le32_to_cpu(layout->magic) != EROFS_SUPER_MAGIC_V1) { + if (le32_to_cpu(dsb->magic) != EROFS_SUPER_MAGIC_V1) { errln("cannot find valid erofs superblock"); goto out; } - blkszbits = layout->blkszbits; + blkszbits = dsb->blkszbits; /* 9(512 bytes) + LOG_SECTORS_PER_BLOCK == LOG_BLOCK_SIZE */ if (blkszbits != LOG_BLOCK_SIZE) { errln("blksize %u isn't supported on this platform", @@ -97,25 +96,25 @@ static int superblock_read(struct super_block *sb) goto out; } - if (!check_layout_compatibility(sb, layout)) + if (!check_layout_compatibility(sb, dsb)) goto out; - sbi->blocks = le32_to_cpu(layout->blocks); - sbi->meta_blkaddr = le32_to_cpu(layout->meta_blkaddr); + sbi->blocks = le32_to_cpu(dsb->blocks); + sbi->meta_blkaddr = le32_to_cpu(dsb->meta_blkaddr); #ifdef CONFIG_EROFS_FS_XATTR - sbi->xattr_blkaddr = le32_to_cpu(layout->xattr_blkaddr); + sbi->xattr_blkaddr = le32_to_cpu(dsb->xattr_blkaddr); #endif sbi->islotbits = ilog2(sizeof(struct erofs_inode_compact)); - sbi->root_nid = le16_to_cpu(layout->root_nid); - sbi->inos = le64_to_cpu(layout->inos); + sbi->root_nid = le16_to_cpu(dsb->root_nid); + sbi->inos = le64_to_cpu(dsb->inos); - sbi->build_time = le64_to_cpu(layout->build_time); - sbi->build_time_nsec = le32_to_cpu(layout->build_time_nsec); + sbi->build_time = le64_to_cpu(dsb->build_time); + sbi->build_time_nsec = le32_to_cpu(dsb->build_time_nsec); - memcpy(&sb->s_uuid, layout->uuid, sizeof(layout->uuid)); + memcpy(&sb->s_uuid, dsb->uuid, sizeof(dsb->uuid)); - ret = strscpy(sbi->volume_name, layout->volume_name, - sizeof(layout->volume_name)); + ret = strscpy(sbi->volume_name, dsb->volume_name, + sizeof(dsb->volume_name)); if (ret < 0) { /* -E2BIG */ errln("bad volume name without NIL terminator"); ret = -EFSCORRUPTED; |