power: supply: bq24190_charger: Program charger with fwnode supplied ccc_ireg and cvc_vreg
So far the bq24190_charger driver has been relying on either the chips default constant_charge_current_max_ua and constant_charge_voltage_max_uv values, or on the BIOS or bootloader to program these for us. This does not happen on all boards, causing e.g. the wrong (too low) values to be used on Lenovo Yoga Tablet 2 830F/L and 1050F/L tablets. If power_supply_get_battery_info() provides us with values for these settings, then program the charger accordingly. And if the user later overrides these values then save the user-values so that these will be restored after a suspend/resume. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r--drivers/power/supply/bq24190_charger.c51
1 files changed, 49 insertions, 2 deletions
diff --git a/drivers/power/supply/bq24190_charger.c b/drivers/power/supply/bq24190_charger.c
index cb36ccbb731a..974e4b6b8d4d 100644
--- a/drivers/power/supply/bq24190_charger.c
+++ b/drivers/power/supply/bq24190_charger.c
@@ -165,7 +165,9 @@ struct bq24190_dev_info {
u16 sys_min;
u16 iprechg;
u16 iterm;
+ u32 ichg;
u32 ichg_max;
+ u32 vreg;
u32 vreg_max;
struct mutex f_reg_lock;
u8 f_reg;
@@ -662,6 +664,28 @@ static int bq24190_set_config(struct bq24190_dev_info *bdi)
return ret;
}
+ if (bdi->ichg) {
+ ret = bq24190_set_field_val(bdi, BQ24190_REG_CCC,
+ BQ24190_REG_CCC_ICHG_MASK,
+ BQ24190_REG_CCC_ICHG_SHIFT,
+ bq24190_ccc_ichg_values,
+ ARRAY_SIZE(bq24190_ccc_ichg_values),
+ bdi->ichg);
+ if (ret < 0)
+ return ret;
+ }
+
+ if (bdi->vreg) {
+ ret = bq24190_set_field_val(bdi, BQ24190_REG_CVC,
+ BQ24190_REG_CVC_VREG_MASK,
+ BQ24190_REG_CVC_VREG_SHIFT,
+ bq24190_cvc_vreg_values,
+ ARRAY_SIZE(bq24190_cvc_vreg_values),
+ bdi->vreg);
+ if (ret < 0)
+ return ret;
+ }
+
return 0;
}
@@ -995,10 +1019,16 @@ static int bq24190_charger_set_current(struct bq24190_dev_info *bdi,
if (v)
curr *= 5;
- return bq24190_set_field_val(bdi, BQ24190_REG_CCC,
+ ret = bq24190_set_field_val(bdi, BQ24190_REG_CCC,
BQ24190_REG_CCC_ICHG_MASK, BQ24190_REG_CCC_ICHG_SHIFT,
bq24190_ccc_ichg_values,
ARRAY_SIZE(bq24190_ccc_ichg_values), curr);
+ if (ret < 0)
+ return ret;
+
+ bdi->ichg = curr;
+
+ return 0;
}
static int bq24190_charger_get_voltage(struct bq24190_dev_info *bdi,
@@ -1020,10 +1050,18 @@ static int bq24190_charger_get_voltage(struct bq24190_dev_info *bdi,
static int bq24190_charger_set_voltage(struct bq24190_dev_info *bdi,
const union power_supply_propval *val)
{
- return bq24190_set_field_val(bdi, BQ24190_REG_CVC,
+ int ret;
+
+ ret = bq24190_set_field_val(bdi, BQ24190_REG_CVC,
BQ24190_REG_CVC_VREG_MASK, BQ24190_REG_CVC_VREG_SHIFT,
bq24190_cvc_vreg_values,
ARRAY_SIZE(bq24190_cvc_vreg_values), val->intval);
+ if (ret < 0)
+ return ret;
+
+ bdi->vreg = val->intval;
+
+ return 0;
}
static int bq24190_charger_get_iinlimit(struct bq24190_dev_info *bdi,
@@ -1701,6 +1739,15 @@ static int bq24190_get_config(struct bq24190_dev_info *bdi)
else
dev_warn(bdi->dev, "invalid value for battery:charge-term-current-microamp: %d\n",
v);
+
+ /* These are optional, so no warning when not set */
+ v = info->constant_charge_current_max_ua;
+ if (v >= bq24190_ccc_ichg_values[0] && v <= bdi->ichg_max)
+ bdi->ichg = v;
+
+ v = info->constant_charge_voltage_max_uv;
+ if (v >= bq24190_cvc_vreg_values[0] && v <= bdi->vreg_max)
+ bdi->vreg = v;
}
return 0;