summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorDarrick J. Wong <djwong@us.ibm.com>2008-08-15 00:40:40 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2008-08-15 08:35:44 -0700
commiteb93b7df7e66597fa807e34a0f812ffff7ff165b (patch)
tree64e0397f7bce520291fa9d4651933e39e85d3be5 /Documentation
parent4ef664b5bc93bbfe28513165216a8c9f4fad5314 (diff)
downloadlinux-eb93b7df7e66597fa807e34a0f812ffff7ff165b.tar.bz2
ibmaem: update the documentation to reflect the current name
Minor documentation update to reflect the current full name of the power management hardware interface and reflows the text a bit. Signed-off-by: Darrick J. Wong <djwong@us.ibm.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/ibmaem33
1 files changed, 17 insertions, 16 deletions
diff --git a/Documentation/hwmon/ibmaem b/Documentation/hwmon/ibmaem
index 2fefaf582a43..e98bdfea3467 100644
--- a/Documentation/hwmon/ibmaem
+++ b/Documentation/hwmon/ibmaem
@@ -1,8 +1,11 @@
Kernel driver ibmaem
======================
+This driver talks to the IBM Systems Director Active Energy Manager, known
+henceforth as AEM.
+
Supported systems:
- * Any recent IBM System X server with Active Energy Manager support.
+ * Any recent IBM System X server with AEM support.
This includes the x3350, x3550, x3650, x3655, x3755, x3850 M2,
x3950 M2, and certain HS2x/LS2x/QS2x blades. The IPMI host interface
driver ("ipmi-si") needs to be loaded for this driver to do anything.
@@ -14,24 +17,22 @@ Author: Darrick J. Wong
Description
-----------
-This driver implements sensor reading support for the energy and power
-meters available on various IBM System X hardware through the BMC. All
-sensor banks will be exported as platform devices; this driver can talk
-to both v1 and v2 interfaces. This driver is completely separate from the
-older ibmpex driver.
+This driver implements sensor reading support for the energy and power meters
+available on various IBM System X hardware through the BMC. All sensor banks
+will be exported as platform devices; this driver can talk to both v1 and v2
+interfaces. This driver is completely separate from the older ibmpex driver.
-The v1 AEM interface has a simple set of features to monitor energy use.
-There is a register that displays an estimate of raw energy consumption
-since the last BMC reset, and a power sensor that returns average power
-use over a configurable interval.
+The v1 AEM interface has a simple set of features to monitor energy use. There
+is a register that displays an estimate of raw energy consumption since the
+last BMC reset, and a power sensor that returns average power use over a
+configurable interval.
-The v2 AEM interface is a bit more sophisticated, being able to present
-a wider range of energy and power use registers, the power cap as
-set by the AEM software, and temperature sensors.
+The v2 AEM interface is a bit more sophisticated, being able to present a wider
+range of energy and power use registers, the power cap as set by the AEM
+software, and temperature sensors.
Special Features
----------------
-The "power_cap" value displays the current system power cap, as set by
-the Active Energy Manager software. Setting the power cap from the host
-is not currently supported.
+The "power_cap" value displays the current system power cap, as set by the AEM
+software. Setting the power cap from the host is not currently supported.